ADVANCE ELECTRICAL KNOWLEDGE

ELECTRICAL TOOLS NAME
S.NO.
TOOLS NAME
REMARK
1
Grinder(cutter) with blade

2
Pana(ring spanner)
3
D-spanner
4
Drill machine
5
Rachet set(goti set)
6
Climping tools
7
Plier & nose plier
9
Tester
10
Scrow driver
11
Hexa blade
12
Slip
13
Gland
14
Thimble(Lugs)
15
Blade/knife
16
120mm/240mm,4core cable
17
Tape
18
Bus-Bar
19
Cable Tie
20
Steel wire
21
Measuring Tape
22
Hammer
23
Wire sciper
24
Holsa cutter with chucknut
25
Hammer machine
26
Hilty machine
27
ceiling rose
28
Bracket








Circuit breaker-When any circuit in unhealthy or unbalance condition then the circuit will be break,is called circuit breaker.like relay.mcb,mccb,rccbetc.it is protective device.it like a fuse.
C.B
1-Air c.b(A.C.B)
2-vacum c.b(V.C.B)
3-Oil c.b(O.C.B)
4-Air c.b(A.B.C.B)



Switch gear-Switch gear is switching,controlling and protective device,like isolator,M.C.B,M.C.C.B,R.C.C.B,E.L.C.B relay etc.
M.C.B-Miniature circuit breaker.
R.C.C.B-Residual current c.b
E.L.C.B-Earth leakage circuit breaker.
M.P.C.B-motor protection circuit breaker.
P.I.U-Power interface unit.
D.G- Diesel generator.
T.P-Three phase
D.P-Double phase
S.P-Single phase
L.D.B-Light distribution board
H.T-High tension(up to 11000v)
L.T-Low tension(below 11000v)
                                                                    All those devices which are used for controlling,switching and protective of circuit is called switchgear.
M.C.B
1-Single pole(SP)
2-Double pole(DP)
3-Three pole(T.P)
4-Four pole(F.P)

Isolator- It is used before & after of transformer.isolator is also type of circuit breaker.thisis helpful for maintenance of transformer.
Relay- Relay is electrimechanical device.this is also is in switchgear.
RELAY
1-Glass relay
2-Thermal relay
3-Solid state rlay



Recloser-Recloser is also type of circuit breaker.

Bus-Bar-This is used for join two wire.This is an conductor copper split.This is used in control panel.

EARTHING
1-Plate earthing
2-Pipe earthing
3-Chemical earthing





CABLE TRAY
1-Perforated type
2-Ladder type





CABLE
1-Single core
2-Double core
3-Three core
4-3.5 core
5-4core


SITE WORK LEVEL
1-Unskills (Electrician/Helper)
2-Semi skills(Supervisor)
3-Skills(junior engg.)
4-High Skills




For load calculation:-
                                                 P=V.I
Note-if any fault in circuit then 1st off all relay inform to circuit breaker then break the circuit.
For 240mm,4core cable gland no-011
For 120mm,4core cable gland no-09
For 70mm,4core cable gland no-04




THREE PHASE
1-Red(R)
2-YELLOW(Y)
3-BLUE(B)


M.C.B
1-6 amp.
2-10 amp.
3-16 amp.
4-20 amp.
5-25 amp.
6-32 amp.
7-40 amp.
8-63 amp.
9-100 amp.
10-125 amp.

Power Transformer(P.T)-Convert 33kv to 11kv(H.T to L.T).
Distribution Transformer(D.T)-Convert 11kv to 440v/220v.
Current Transformer(C.T)-Measure current of Transformer.
Potential Transformer(P.T)-Measure voltage of transformer.
Lightning Arrester(L.A)-This is used protection of transformer.

DTR Structure-

Following material are required for installation of transformer:-
S.NO.
Material Description
1
VCB HT panel
2
ACB panel
3
3*95 H.T cable
4
4*120 LT cable
5
2*70 LT(AT) cable
6
Transformer 250KVA
7
Transformer 500KVA
8
Transformer 1.6 MVA
9
11kv disc insulator
10
11kv Pin insulator
11
Lighning Arrester
12
LT panel without ACB
13
Pipe earthing material